Request a Safety Valve Quote

Share your medium, set pressure, temperature, size,standard, or datasheet, and our team will review yourrequirement and respond with the appropriate next step.

ZBAHN42F-P18; ZBWAHN42F-P18 Parallel Safety Reflux Valve

Parallel Safety Reflux Valve for LPG station pump outlet liquid-phase reflux pipelines, automatic safe return when pump pressure exceeds set value. Key selection data include DN40-DN100, P18 service rating per model code, For LPG liquid-phase reflux service, confirm project temperature, materials, connection standard and set pressure.

Final set pressure, certified relieving capacity, material code and connection standard must be confirmed on the approved datasheet before purchase.

ZBAHN42F-P18; ZBWAHN42F-P18 Parallel Safety Reflux Valve product image
Actual product image for ZBAHN42F-P18; ZBWAHN42F-P18 Parallel Safety Reflux Valve.

Technical Specifications and Selection Data

Product Model

ZBAHN42F-P18; ZBWAHN42F-P18

Size Range

DN40-DN100

Pressure Rating

P18 service rating per model code

Temperature Range

For LPG liquid-phase reflux service, confirm project temperature

Applicable Media

Liquefied petroleum gas liquid-phase reflux line

Connection Type

Flanged parallel reflux valve connection

Standards and Compliance

GB/T 12241, GB/T 12242 and GB/T 12243 for safety valve design, performance and test references; model coding follows the JB/T 308 valve model method where applicable.

Engineering Insight: Model Logic and Application Boundary

Model code: AHN42F/WAHN42F = safety reflux valve configuration; P18 identifies service pressure/material code in catalog.

Typical application: LPG station pump outlet liquid-phase reflux pipelines, automatic safe return when pump pressure exceeds set value

Capacity review: Main connection dimensions are listed on the source catalog page. Discharge capacity and orifice sizing should be confirmed by set pressure, medium, temperature and applicable code.

This product family should not be selected from model code, nominal size or pressure class alone. Confirm the relieving scenario, required capacity, set pressure, operating margin, temperature, back pressure and actual connection standard.

Dimensions and Selection Guide

The table below is transcribed from catalog page 28. Verify critical dimensions against the approved order drawing before fabrication or piping release.

Catalog page 028 – Parameter Table 1
Nominal Diameter (DN)Nominal Diameter (DN)doG1GLL1Approx. H
40 50 65 1001501 10851 646130200346
40 50 65 10016012510046130230346
40 50 65 1001801451202046130290440
40 50 65 100195160135208 8310540
40 50 65 1002151801552246252350570

RFQ checklist

RFQ checklist: model or valve type, DN/NPS, PN/Class, set pressure, relieving medium, operating temperature, body and trim material, inlet/outlet connection standard, cap/lever/pilot options, quantity, drawing, certificate and inspection requirements.

Failure Analysis, Manufacturing Evidence and Quality Control

Common misapplication risks: incorrect thread or connection standard, insufficient certified relieving capacity, unsuitable body or trim material, operating pressure too close to set pressure, unreviewed back pressure, and installation loads transferred to the valve.

Material review: body materials: WCB carbon steel, ZG15Cr1Mo alloy steel, ZG15Cr1Mo1V/ZG20Cr1Mo1V high-temperature alloy steel, CF8/304, CF8M/316 or CF3M/316L according to model body code and service. Trim and internals: 20Cr13, 304, 316, 316L or alloy trim according to body code and medium; corrosive or high-temperature service can use stainless or alloy internals. Spring and stem: 50CrVA spring for standard service; stainless or coated fluoroplastic/304 spring options for corrosive service where specified.

Testing and inspection: Set pressure calibration, shell strength test, seat tightness/leakage test, reseating/blowdown check, dimensional inspection and material verification can be supplied according to the confirmed standard and order requirements.

Source and scope: product data is based on Zobai Safety Valve Product Catalog.pdf, catalog page 28. Project compliance remains subject to the approved datasheet, drawing, calculation and controlled certificates for the ordered configuration.

Review material traceability, type-test scope and project certificate requirements.

Related Products

FAQ

Safety Valve FAQs

Size: DN40-DN100. Pressure: P18 service rating per model code. Temperature: For LPG liquid-phase reflux service, confirm project temperature. Confirm the exact combination for the selected model.

Liquefied petroleum gas liquid-phase reflux line. Material and sealing compatibility require review for the actual fluid composition and temperature.

Use it for preliminary review only. Confirm critical dimensions, connection details and orientation on the approved order drawing before piping or equipment fabrication.

RFQ checklist: model or valve type, DN/NPS, PN/Class, set pressure, relieving medium, operating temperature, body and trim material, inlet/outlet connection standard, cap/lever/pilot options, quantity, drawing, certificate and inspection requirements.