Request a Safety Valve Quote

Share your medium, set pressure, temperature, size,standard, or datasheet, and our team will review yourrequirement and respond with the appropriate next step.

ZBA42F-16C; ZBAH42F-16C LPG Safety Valve and Safety Reflux Valve

LPG Safety Valve and Safety Reflux Valve for LPG storage, LPG pump outlet reflux pipelines and non-corrosive liquefied gas overpressure protection. Key selection data include Catalog dimension table by DN, confirm final DN from LPG service, PN16, -29 deg C to +80 deg C, materials, connection standard and set pressure.

Final set pressure, certified relieving capacity, material code and connection standard must be confirmed on the approved datasheet before purchase.

ZBA42F-16C; ZBAH42F-16C LPG Safety Valve and Safety Reflux Valve product image
Actual product image for ZBA42F-16C; ZBAH42F-16C LPG Safety Valve and Safety Reflux Valve.

Technical Specifications and Selection Data

Product Model

ZBA42F-16C; ZBAH42F-16C

Size Range

Catalog dimension table by DN, confirm final DN from LPG service

Pressure Rating

PN16

Temperature Range

-29 deg C to +80 deg C

Applicable Media

Liquefied petroleum gas and similar non-corrosive media; AH42F is for LPG station pump outlet liquid-phase reflux line

Connection Type

Flanged connection

Standards and Compliance

GB/T 12241, GB/T 12242 and GB/T 12243 for safety valve design, performance and test references; model coding follows the JB/T 308 valve model method where applicable.

Engineering Insight: Model Logic and Application Boundary

Model code: A42F = full-lift safety valve with soft sealing surface; AH42F = safety reflux configuration for LPG liquid return service.

Typical application: LPG storage, LPG pump outlet reflux pipelines and non-corrosive liquefied gas overpressure protection

Capacity review: Main connection dimensions are listed on the source catalog page. Discharge capacity and orifice sizing should be confirmed by set pressure, medium, temperature and applicable code.

This product family should not be selected from model code, nominal size or pressure class alone. Confirm the relieving scenario, required capacity, set pressure, operating margin, temperature, back pressure and actual connection standard.

Dimensions and Selection Guide

The table below is transcribed from catalog page 27. Verify critical dimensions against the approved order drawing before fabrication or piping release.

Catalog page 027 – Parameter Table 1
Nominal Diameter (DN)doNominal Diameter (DN)LL1Approx. H
20 25 32 40 501 5251 1095281
20 25 32 40 50321 1095281
20 25 32 40 5020401 15100285
20 25 32 40 5025501201 10295
20 25 32 40 503265135120305
65 80 100 125 1504080160140394
65 80 100 125 15050100170135406
65 80 100 125 15065125205160511
65 80 100 125 15080150210190586
65 80 100 125 150100175255230601
200 250 300 350125250305260734
200 250 300 350150300350320928
200 250 300 3502004003703501 159
200 250 300 3502505003754151314

RFQ checklist

RFQ checklist: model or valve type, DN/NPS, PN/Class, set pressure, relieving medium, operating temperature, body and trim material, inlet/outlet connection standard, cap/lever/pilot options, quantity, drawing, certificate and inspection requirements.

Failure Analysis, Manufacturing Evidence and Quality Control

Common misapplication risks: incorrect thread or connection standard, insufficient certified relieving capacity, unsuitable body or trim material, operating pressure too close to set pressure, unreviewed back pressure, and installation loads transferred to the valve.

Material review: body materials: WCB carbon steel, ZG15Cr1Mo alloy steel, ZG15Cr1Mo1V/ZG20Cr1Mo1V high-temperature alloy steel, CF8/304, CF8M/316 or CF3M/316L according to model body code and service. Trim and internals: 20Cr13, 304, 316, 316L or alloy trim according to body code and medium; corrosive or high-temperature service can use stainless or alloy internals. Spring and stem: 50CrVA spring for standard service; stainless or coated fluoroplastic/304 spring options for corrosive service where specified.

Testing and inspection: Set pressure calibration, shell strength test, seat tightness/leakage test, reseating/blowdown check, dimensional inspection and material verification can be supplied according to the confirmed standard and order requirements.

Source and scope: product data is based on Zobai Safety Valve Product Catalog.pdf, catalog page 27. Project compliance remains subject to the approved datasheet, drawing, calculation and controlled certificates for the ordered configuration.

Review material traceability, type-test scope and project certificate requirements.

Related Products

FAQ

Safety Valve FAQs

Size: Catalog dimension table by DN, confirm final DN from LPG service. Pressure: PN16. Temperature: -29 deg C to +80 deg C. Confirm the exact combination for the selected model.

Liquefied petroleum gas and similar non-corrosive media; AH42F is for LPG station pump outlet liquid-phase reflux line. Material and sealing compatibility require review for the actual fluid composition and temperature.

Use it for preliminary review only. Confirm critical dimensions, connection details and orientation on the approved order drawing before piping or equipment fabrication.

RFQ checklist: model or valve type, DN/NPS, PN/Class, set pressure, relieving medium, operating temperature, body and trim material, inlet/outlet connection standard, cap/lever/pilot options, quantity, drawing, certificate and inspection requirements.