{"id":55415,"date":"2026-06-24T02:46:56","date_gmt":"2026-06-24T02:46:56","guid":{"rendered":"https:\/\/zobai.com\/?p=55415"},"modified":"2026-06-24T02:46:57","modified_gmt":"2026-06-24T02:46:57","slug":"what-is-a-threaded-safety-valve","status":"publish","type":"post","link":"https:\/\/zobai.com\/it\/blog\/what-is-a-threaded-safety-valve\/","title":{"rendered":"Cos'\u00e8 una valvola di sicurezza filettata?"},"content":{"rendered":"\n<style>\n.zobai-threaded-sv-page{\n  --z-primary:#0f766e;\n  --z-primary-dark:#0b4f4a;\n  --z-accent:#16a085;\n  --z-text:#20262d;\n  --z-muted:#5f6b75;\n  --z-line:#dfe6e8;\n  --z-soft:#f2f8f6;\n  --z-soft-2:#eef6f3;\n  --z-warning:#fff7ed;\n  --z-warning-line:#fed7aa;\n  --z-danger-soft:#fff1f2;\n  --z-danger-line:#fecdd3;\n  --z-radius-md:16px;\n  --z-radius-lg:24px;\n  --z-shadow:0 18px 50px rgba(15,118,110,.10);\n  --z-container:1180px;\n  box-sizing:border-box;\n  color:var(--z-text);\n  font-family:inherit;\n  line-height:1.68;\n  overflow-wrap:break-word;\n}\n\n.zobai-threaded-sv-page .zobai-container,\n.zobai-threaded-sv-page .zobai-hero,\n.zobai-threaded-sv-page .zobai-hero-summary,\n.zobai-threaded-sv-page .zobai-hero-summary-item,\n.zobai-threaded-sv-page .zobai-hero-actions,\n.zobai-threaded-sv-page .zobai-toc,\n.zobai-threaded-sv-page .zobai-section,\n.zobai-threaded-sv-page .zobai-card,\n.zobai-threaded-sv-page .zobai-grid,\n.zobai-threaded-sv-page .zobai-table-wrap,\n.zobai-threaded-sv-page .zobai-figure,\n.zobai-threaded-sv-page .zobai-rfq,\n.zobai-threaded-sv-page .zobai-faq,\n.zobai-threaded-sv-page .zobai-note,\n.zobai-threaded-sv-page .zobai-related,\n.zobai-threaded-sv-page .zobai-process,\n.zobai-threaded-sv-page .zobai-process-step{\n  box-sizing:border-box;\n}\n\n.zobai-threaded-sv-page [id]{\n  scroll-margin-top:92px;\n}\n\n.zobai-threaded-sv-page .zobai-container{\n  max-width:var(--z-container);\n  margin:0 auto;\n  padding:0 22px;\n}\n\n.zobai-threaded-sv-page .zobai-hero{\n  background:linear-gradient(135deg,#ecf8f5 0%,#ffffff 58%,#f8fbfa 100%);\n  border:1px solid var(--z-line);\n  border-radius:var(--z-radius-lg);\n  padding:46px;\n  box-shadow:var(--z-shadow);\n  margin:0 auto 28px;\n}\n\n.zobai-threaded-sv-page .zobai-eyebrow{\n  display:inline-flex;\n  align-items:center;\n  gap:8px;\n  font-size:13px;\n  font-weight:700;\n  letter-spacing:.08em;\n  text-transform:uppercase;\n  color:var(--z-primary-dark);\n  background:#dff3ee;\n  border:1px solid #bfe6dd;\n  border-radius:999px;\n  padding:7px 12px;\n  margin:0 0 18px;\n}\n\n.zobai-threaded-sv-page .zobai-hero-title{\n  font-size:clamp(30px,4vw,52px);\n  line-height:1.12;\n  letter-spacing:-.03em;\n  color:var(--z-primary-dark);\n  margin:0 0 18px;\n}\n\n.zobai-threaded-sv-page .zobai-hero-lead{\n  font-size:clamp(17px,2vw,20px);\n  color:#34424a;\n  max-width:960px;\n  margin:0 0 20px;\n}\n\n.zobai-threaded-sv-page .zobai-hero-summary{\n  display:grid;\n  grid-template-columns:repeat(3,minmax(0,1fr));\n  gap:14px;\n  margin:24px 0 0;\n}\n\n.zobai-threaded-sv-page .zobai-hero-summary-item{\n  background:#fff;\n  border:1px solid #cfe5df;\n  border-radius:var(--z-radius-md);\n  padding:16px;\n}\n\n.zobai-threaded-sv-page .zobai-hero-summary-item strong{\n  display:block;\n  color:var(--z-primary-dark);\n  margin-bottom:5px;\n}\n\n.zobai-threaded-sv-page .zobai-hero-summary-item span{\n  color:var(--z-muted);\n  font-size:14px;\n}\n\n.zobai-threaded-sv-page .zobai-hero-actions{\n  display:flex;\n  flex-wrap:wrap;\n  gap:12px;\n  margin-top:24px;\n}\n\n.zobai-threaded-sv-page .zobai-btn{\n  display:inline-flex;\n  align-items:center;\n  justify-content:center;\n  min-height:46px;\n  padding:12px 18px;\n  border-radius:999px;\n  text-decoration:none;\n  font-weight:700;\n  border:1px solid transparent;\n  transition:transform .18s ease,box-shadow .18s ease,background .18s ease;\n}\n\n.zobai-threaded-sv-page .zobai-btn-primary{\n  color:#fff;\n  background:var(--z-primary);\n  box-shadow:0 10px 24px rgba(15,118,110,.22);\n}\n\n.zobai-threaded-sv-page .zobai-btn-secondary{\n  color:var(--z-primary-dark);\n  background:#fff;\n  border-color:#b7d9d3;\n}\n\n.zobai-threaded-sv-page .zobai-btn:hover{\n  transform:translateY(-1px);\n}\n\n.zobai-threaded-sv-page .zobai-btn:focus,\n.zobai-threaded-sv-page .zobai-toc-list a:focus,\n.zobai-threaded-sv-page .zobai-section a:focus{\n  outline:3px solid rgba(22,160,133,.22);\n  outline-offset:3px;\n}\n\n.zobai-threaded-sv-page .zobai-toc{\n  border:1px solid var(--z-line);\n  border-radius:var(--z-radius-md);\n  background:#fff;\n  padding:20px;\n  margin:28px 0;\n}\n\n.zobai-threaded-sv-page .zobai-toc-title{\n  font-weight:800;\n  color:var(--z-primary-dark);\n  margin:0 0 12px;\n}\n\n.zobai-threaded-sv-page .zobai-toc-list{\n  display:flex;\n  flex-wrap:wrap;\n  gap:10px;\n  margin:0;\n  padding:0;\n  list-style:none;\n}\n\n.zobai-threaded-sv-page .zobai-toc-list a{\n  display:inline-flex;\n  text-decoration:none;\n  color:var(--z-primary-dark);\n  background:var(--z-soft);\n  border:1px solid #d6ece7;\n  border-radius:999px;\n  padding:8px 12px;\n  font-size:14px;\n  font-weight:650;\n  overflow-wrap:anywhere;\n}\n\n.zobai-threaded-sv-page .zobai-section{\n  margin:44px 0;\n}\n\n.zobai-threaded-sv-page .zobai-section h2{\n  font-size:clamp(25px,3vw,36px);\n  line-height:1.22;\n  letter-spacing:-.02em;\n  color:var(--z-primary-dark);\n  margin:0 0 18px;\n}\n\n.zobai-threaded-sv-page .zobai-section h3{\n  font-size:clamp(19px,2vw,24px);\n  line-height:1.28;\n  color:#163d39;\n  margin:26px 0 10px;\n}\n\n.zobai-threaded-sv-page .zobai-section p{\n  margin:0 0 16px;\n}\n\n.zobai-threaded-sv-page .zobai-section a{\n  color:var(--z-primary-dark);\n  font-weight:700;\n  text-decoration-thickness:2px;\n  text-underline-offset:3px;\n  overflow-wrap:anywhere;\n}\n\n.zobai-threaded-sv-page .zobai-quick-answer{\n  border-left:5px solid var(--z-primary);\n  background:var(--z-soft);\n  border-radius:0 var(--z-radius-md) var(--z-radius-md) 0;\n  padding:24px;\n  margin:28px 0;\n}\n\n.zobai-threaded-sv-page .zobai-grid{\n  display:grid;\n  grid-template-columns:repeat(3,minmax(0,1fr));\n  gap:18px;\n  margin:22px 0;\n}\n\n.zobai-threaded-sv-page .zobai-grid-2{\n  grid-template-columns:repeat(2,minmax(0,1fr));\n}\n\n.zobai-threaded-sv-page .zobai-card{\n  background:#fff;\n  border:1px solid var(--z-line);\n  border-radius:var(--z-radius-md);\n  padding:20px;\n  box-shadow:0 10px 28px rgba(25,48,54,.05);\n}\n\n.zobai-threaded-sv-page .zobai-card h3{\n  margin-top:0;\n}\n\n.zobai-threaded-sv-page .zobai-card p{\n  margin-bottom:0;\n}\n\n.zobai-threaded-sv-page .zobai-card-caution{\n  background:var(--z-danger-soft);\n  border-color:var(--z-danger-line);\n}\n\n.zobai-threaded-sv-page .zobai-table-wrap{\n  overflow-x:auto;\n  border:1px solid var(--z-line);\n  border-radius:var(--z-radius-md);\n  background:#fff;\n  margin:22px 0;\n  -webkit-overflow-scrolling:touch;\n}\n\n.zobai-threaded-sv-page .zobai-table-wrap:focus{\n  outline:3px solid rgba(22,160,133,.20);\n  outline-offset:3px;\n}\n\n.zobai-threaded-sv-page .zobai-table{\n  width:100%;\n  border-collapse:collapse;\n  min-width:820px;\n}\n\n.zobai-threaded-sv-page .zobai-table th,\n.zobai-threaded-sv-page .zobai-table td{\n  text-align:left;\n  vertical-align:top;\n  padding:14px 16px;\n  border-bottom:1px solid var(--z-line);\n}\n\n.zobai-threaded-sv-page .zobai-table th{\n  background:var(--z-soft) !important;\n  color:var(--z-primary-dark) !important;\n  font-weight:800;\n}\n\n.zobai-threaded-sv-page .zobai-table tr:last-child td{\n  border-bottom:0;\n}\n\n.zobai-threaded-sv-page .zobai-figure{\n  margin:26px 0;\n  border:1px solid var(--z-line);\n  border-radius:var(--z-radius-md);\n  background:#fff;\n  overflow:hidden;\n}\n\n.zobai-threaded-sv-page .zobai-figure-img{\n  display:block;\n  width:100%;\n  height:auto;\n  aspect-ratio:4\/3;\n  object-fit:cover;\n  background:#f8fbfa;\n}\n\n.zobai-threaded-sv-page .zobai-figure figcaption{\n  padding:12px 16px;\n  color:#34424a;\n  font-size:14px;\n  border-top:1px solid var(--z-line);\n  background:#fbfdfc;\n}\n\n.zobai-threaded-sv-page .zobai-figure-note{\n  padding:0 16px 14px;\n  margin:0;\n  color:var(--z-muted);\n  font-size:13px;\n}\n\n.zobai-threaded-sv-page .zobai-callout{\n  background:var(--z-warning);\n  border:1px solid var(--z-warning-line);\n  border-radius:var(--z-radius-md);\n  padding:20px;\n  margin:22px 0;\n}\n\n.zobai-threaded-sv-page .zobai-callout strong{\n  color:#7c2d12;\n}\n\n.zobai-threaded-sv-page .zobai-rfq{\n  background:linear-gradient(135deg,#0f766e,#0b4f4a);\n  color:#fff;\n  border-radius:var(--z-radius-lg);\n  padding:30px;\n  margin:42px 0;\n}\n\n.zobai-threaded-sv-page .zobai-rfq h2,\n.zobai-threaded-sv-page .zobai-rfq h3{\n  color:#fff;\n}\n\n.zobai-threaded-sv-page .zobai-rfq p{\n  color:#e8fffb;\n}\n\n.zobai-threaded-sv-page .zobai-rfq .zobai-btn-secondary{\n  background:#fff;\n  color:#0b4f4a;\n}\n\n.zobai-threaded-sv-page .zobai-checklist{\n  margin:16px 0 0;\n  padding:0;\n  list-style:none;\n}\n\n.zobai-threaded-sv-page .zobai-checklist li{\n  position:relative;\n  padding-left:28px;\n  margin:10px 0;\n}\n\n.zobai-threaded-sv-page .zobai-checklist li::before{\n  content:\"\u2713\";\n  position:absolute;\n  left:0;\n  top:0;\n  color:var(--z-accent);\n  font-weight:900;\n}\n\n.zobai-threaded-sv-page .zobai-card-caution .zobai-checklist li::before{\n  content:\"!\";\n  background:#be123c;\n  color:#fff;\n  width:18px;\n  height:18px;\n  border-radius:50%;\n  display:inline-flex;\n  align-items:center;\n  justify-content:center;\n  font-size:12px;\n  top:4px;\n}\n\n.zobai-threaded-sv-page .zobai-process{\n  counter-reset:zobai-step;\n  display:grid;\n  grid-template-columns:repeat(4,minmax(0,1fr));\n  gap:14px;\n  margin:22px 0;\n}\n\n.zobai-threaded-sv-page .zobai-process-step{\n  counter-increment:zobai-step;\n  background:#fff;\n  border:1px solid var(--z-line);\n  border-radius:var(--z-radius-md);\n  padding:18px;\n}\n\n.zobai-threaded-sv-page .zobai-process-step::before{\n  content:counter(zobai-step);\n  display:inline-flex;\n  width:30px;\n  height:30px;\n  align-items:center;\n  justify-content:center;\n  border-radius:50%;\n  background:var(--z-primary);\n  color:#fff;\n  font-weight:800;\n  margin-bottom:10px;\n}\n\n.zobai-threaded-sv-page .zobai-process-step strong{\n  display:block;\n  color:var(--z-primary-dark);\n  margin-bottom:6px;\n}\n\n.zobai-threaded-sv-page .zobai-faq{\n  border:1px solid var(--z-line);\n  border-radius:var(--z-radius-md);\n  background:#fff;\n  padding:22px;\n  margin:16px 0;\n}\n\n.zobai-threaded-sv-page .zobai-faq h3{\n  margin-top:0;\n}\n\n.zobai-threaded-sv-page .zobai-note{\n  border:1px solid var(--z-line);\n  border-radius:var(--z-radius-md);\n  background:#fff;\n  padding:22px;\n  margin:28px 0;\n}\n\n.zobai-threaded-sv-page .zobai-reference-list{\n  margin:14px 0 0;\n  padding-left:20px;\n}\n\n.zobai-threaded-sv-page .zobai-reference-list li{\n  margin:10px 0;\n}\n\n.zobai-threaded-sv-page .zobai-reference-list span{\n  color:var(--z-muted);\n}\n\n.zobai-threaded-sv-page .zobai-related{\n  background:var(--z-soft-2);\n  border:1px solid #d2e8e2;\n  border-radius:var(--z-radius-md);\n  padding:22px;\n}\n\n.zobai-threaded-sv-page .zobai-related ul{\n  margin:12px 0 0;\n  padding-left:20px;\n}\n\n.zobai-threaded-sv-page .zobai-muted{\n  color:var(--z-muted);\n}\n\n@media (max-width:900px){\n  .zobai-threaded-sv-page .zobai-hero{\n    padding:34px 26px;\n  }\n\n  .zobai-threaded-sv-page .zobai-grid,\n  .zobai-threaded-sv-page .zobai-grid-2,\n  .zobai-threaded-sv-page .zobai-hero-summary,\n  .zobai-threaded-sv-page .zobai-process{\n    grid-template-columns:1fr;\n  }\n}\n\n@media (max-width:640px){\n  .zobai-threaded-sv-page .zobai-container{\n    padding:0 16px;\n  }\n\n  .zobai-threaded-sv-page .zobai-hero{\n    padding:28px 20px;\n    border-radius:18px;\n  }\n\n  .zobai-threaded-sv-page .zobai-hero-actions{\n    flex-direction:column;\n  }\n\n  .zobai-threaded-sv-page .zobai-btn{\n    width:100%;\n  }\n\n  .zobai-threaded-sv-page .zobai-table{\n    min-width:760px;\n  }\n}\n\n@media (prefers-reduced-motion:reduce){\n  .zobai-threaded-sv-page .zobai-btn{\n    transition:none;\n  }\n\n  .zobai-threaded-sv-page .zobai-btn:hover{\n    transform:none;\n  }\n}\n<\/style>\n\n<article class=\"zobai-threaded-sv-page\">\n  <div class=\"zobai-container\">\n    <section class=\"zobai-hero\" id=\"overview\">\n      <p class=\"zobai-eyebrow\">Valve Types &amp; Connection Selection<\/p>\n      <h2 class=\"zobai-hero-title\">What Is a Threaded Safety Valve?<\/h2>\n      <p class=\"zobai-hero-lead\">A threaded safety valve is a safety valve or pressure relief valve with threaded end connections instead of flanged, welded, sanitary clamp or other connection types. This page explains what threaded connection means, when it may be considered, when it may create selection risk, and what data must be confirmed before RFQ or replacement. \u201cThreaded\u201d describes the connection style only; it does not prove set pressure, relieving capacity, material suitability, seat tightness, pressure-temperature rating, installation safety or documentation compliance.<\/p>\n      <div class=\"zobai-hero-summary\">\n        <div class=\"zobai-hero-summary-item\">\n          <strong>Main definition<\/strong>\n          <span>A pressure relief device with screwed end connections.<\/span>\n        <\/div>\n        <div class=\"zobai-hero-summary-item\">\n          <strong>Main buyer risk<\/strong>\n          <span>Replacing by thread size, appearance or partial nameplate data alone.<\/span>\n        <\/div>\n        <div class=\"zobai-hero-summary-item\">\n          <strong>RFQ priority<\/strong>\n          <span>Confirm thread form, pressure data, required capacity, medium and documents.<\/span>\n        <\/div>\n      <\/div>\n      <div class=\"zobai-hero-actions\">\n        <a class=\"zobai-btn zobai-btn-primary\" href=\"https:\/\/zobai.com\/ask-an-engineer\/\">Ask a Safety Valve Engineer<\/a>\n        <a class=\"zobai-btn zobai-btn-secondary\" href=\"https:\/\/zobai.com\/safety-valves\/threaded-safety-valves\/\">Review Threaded Safety Valves<\/a>\n      <\/div>\n    <\/section>\n\n&#8220;`\n<figure class=\"zobai-figure\" data-image-status=\"planned\" data-image-slot=\"image-01-hero-threaded-safety-valve\">\n  <img fetchpriority=\"high\" class=\"zobai-figure-img\" src=\"https:\/\/zobai.com\/wp-content\/uploads\/2026\/06\/threaded-safety-valve-overview.webp\" alt=\"Threaded safety valve with visible threaded inlet and outlet connection for pressure relief service\" title=\"Threaded safety valve overview\" width=\"1200\" height=\"900\" loading=\"eager\" fetchpriority=\"high\" decoding=\"async\">\n  <figcaption>A threaded safety valve uses screwed end connections, but thread size alone does not define capacity or suitability.<\/figcaption>\n  <p class=\"zobai-figure-note\">AI-generated engineering visual for article illustration only. Final product appearance, thread type, material, set pressure and capacity must be confirmed against the selected model and project specification.<\/p>\n<\/figure>\n\n<nav class=\"zobai-toc\" aria-label=\"On this page\">\n  <p class=\"zobai-toc-title\">On this page<\/p>\n  <ul class=\"zobai-toc-list\">\n    <li><a href=\"#quick-answer\">Quick answer<\/a><\/li>\n    <li><a href=\"#parts\">Parts and connections<\/a><\/li>\n    <li><a href=\"#thread-types\">Thread types<\/a><\/li>\n    <li><a href=\"#pressure-capacity\">Pressure &amp; capacity<\/a><\/li>\n    <li><a href=\"#applications\">Common use<\/a><\/li>\n    <li><a href=\"#limits\">When not suitable<\/a><\/li>\n    <li><a href=\"#threaded-vs-flanged\">Threaded vs flanged<\/a><\/li>\n    <li><a href=\"#engineering-checks\">Engineering checks<\/a><\/li>\n    <li><a href=\"#rfq-data\">RFQ data<\/a><\/li>\n    <li><a href=\"#mistakes\">Common mistakes<\/a><\/li>\n    <li><a href=\"#replacement-workflow\">Replacement workflow<\/a><\/li>\n    <li><a href=\"#zobai-review\">ZOBAI review<\/a><\/li>\n    <li><a href=\"#faq\">FAQ<\/a><\/li>\n    <li><a href=\"#technical-references\">References<\/a><\/li>\n  <\/ul>\n<\/nav>\n\n<section class=\"zobai-section zobai-quick-answer\" id=\"quick-answer\">\n  <h2>Quick Answer: What Is a Threaded Safety Valve?<\/h2>\n  <p>A <strong>threaded safety valve<\/strong> is a safety valve or <a href=\"https:\/\/zobai.com\/safety-valves\/pressure-relief-valves\/\">pressure relief valve<\/a> with threaded end connections. Buyers may also describe it as a screwed safety valve, threaded pressure relief valve, threaded PSV or threaded PRV.<\/p>\n  <p>The threaded connection may be practical for compact equipment, smaller vessels, utility systems, skids, compressors or replacement applications where the equipment connection is already threaded. But the connection style is only one part of the specification. A correct inquiry must still confirm protected equipment, relief scenario, medium and phase, operating pressure, MAWP or design pressure, set pressure, required relieving capacity, relieving temperature, back pressure, thread type, material, seat\/seal requirements and documents.<\/p>\n  <p>For product-family options, review ZOBAI <a href=\"https:\/\/zobai.com\/safety-valves\/threaded-safety-valves\/\">threaded safety valves<\/a>. For engineering review, send your operating and connection data before quotation or replacement.<\/p>\n<\/section>\n\n<section class=\"zobai-section\" id=\"parts\">\n  <h2>Main Parts and Connection Features of a Threaded Safety Valve<\/h2>\n  <p>A threaded safety valve is still a pressure protection device first. The thread is only the connection method. The valve must still open, relieve, pass the required capacity and reseat correctly under the specified service conditions.<\/p>\n\n  <figure class=\"zobai-figure\" data-image-status=\"planned\" data-image-slot=\"image-02-threaded-connection-close-up\">\n    <img loading=\"lazy\" class=\"zobai-figure-img\" src=\"https:\/\/zobai.com\/wp-content\/uploads\/2026\/06\/threaded-safety-valve-connection-close-up.webp\" alt=\"Close-up of threaded safety valve inlet and outlet connection showing threaded connection details\" title=\"Threaded safety valve connection close-up\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\">\n    <figcaption>Threaded inlet and outlet details must be confirmed before RFQ or replacement.<\/figcaption>\n    <p class=\"zobai-figure-note\">AI-generated engineering visual for connection identification only; it is not a thread standard dimension chart.<\/p>\n  <\/figure>\n\n  <div class=\"zobai-grid\">\n    <div class=\"zobai-card\">\n      <h3>Threaded inlet<\/h3>\n      <p>The inlet connects the valve to protected equipment or upstream piping. Thread type, gender, sealing method, inlet restriction and inlet pressure loss must be reviewed. A threaded inlet connection must not create excessive restriction, blocked flow, sealant intrusion or inlet pressure loss that affects opening behavior or valve stability.<\/p>\n    <\/div>\n    <div class=\"zobai-card\">\n      <h3>Outlet and discharge path<\/h3>\n      <p>The outlet must discharge safely and should not be used to support heavy downstream piping without engineering review.<\/p>\n    <\/div>\n    <div class=\"zobai-card\">\n      <h3>Seat, spring and body<\/h3>\n      <p>Body, trim, seat, seal and spring materials must match medium, temperature, pressure, corrosion risk and document requirements.<\/p>\n    <\/div>\n  <\/div>\n\n  <div class=\"zobai-table-wrap\" role=\"region\" aria-label=\"Threaded safety valve specification table\" tabindex=\"0\">\n    <table class=\"zobai-table\">\n      <thead>\n        <tr>\n          <th>Specification Item<\/th>\n          <th>What to Confirm<\/th>\n          <th>Why It Matters<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>Thread type<\/td>\n          <td>NPT, BSP, G, Rc or project-specific thread.<\/td>\n          <td>Prevents wrong fit, leakage and thread damage.<\/td>\n        <\/tr>\n        <tr>\n          <td>Thread size<\/td>\n          <td>Nominal inlet and outlet size.<\/td>\n          <td>Needed for connection matching, but not capacity proof.<\/td>\n        <\/tr>\n        <tr>\n          <td>Set pressure<\/td>\n          <td>Required opening pressure under specified test conditions.<\/td>\n          <td>Defines pressure setting, not relieving capacity.<\/td>\n        <\/tr>\n        <tr>\n          <td>Required capacity<\/td>\n          <td>Required relieving load and capacity basis.<\/td>\n          <td>Confirms pressure protection capability.<\/td>\n        <\/tr>\n        <tr>\n          <td>Material<\/td>\n          <td>Body, trim, seat, seal and spring.<\/td>\n          <td>Affects corrosion resistance, temperature suitability and documentation.<\/td>\n        <\/tr>\n        <tr>\n          <td>Documents<\/td>\n          <td>Datasheet, nameplate, test records, material records and inspection scope.<\/td>\n          <td>Supports safe procurement and replacement verification.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<section class=\"zobai-section\" id=\"thread-types\">\n  <h2>Common Thread Types: NPT, BSP, G and Rc<\/h2>\n  <p>Threaded safety valves may be described with thread names such as NPT, BSP, G or Rc. These terms are important because thread form affects fit and sealing method. A buyer should confirm the exact thread requirement from the datasheet, drawing, nameplate, equipment port or project piping specification.<\/p>\n\n  <figure class=\"zobai-figure\" data-image-status=\"planned\" data-image-slot=\"image-03-thread-type-confirmation\">\n    <img loading=\"lazy\" class=\"zobai-figure-img\" src=\"https:\/\/zobai.com\/wp-content\/uploads\/2026\/06\/threaded-safety-valve-thread-type-confirmation.webp\" alt=\"Thread type confirmation graphic for NPT, BSP, G and Rc threaded safety valve replacement\" title=\"Thread type confirmation for threaded safety valves\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\">\n    <figcaption>Similar-looking threaded safety valve connections may not be interchangeable without confirming the thread type.<\/figcaption>\n    <p class=\"zobai-figure-note\">AI-generated simplified engineering illustration; it does not replace thread standards, drawings or gauge verification.<\/p>\n  <\/figure>\n\n  <h3>Why similar-looking threads may not be interchangeable<\/h3>\n  <p>A common replacement mistake is assuming that similar-looking threads are interchangeable. They may not be. An NPT threaded valve should not be treated as automatically interchangeable with BSP, G or Rc threads. Thread angle, taper, pitch and sealing method may differ.<\/p>\n\n  <h3>Male\/female thread and sealing method<\/h3>\n  <p>Threaded connections may be male or female. Some connections seal on the thread, while others may rely on a sealing face, gasket, washer or another arrangement. The sealing method must be confirmed rather than assumed.<\/p>\n  <p>Connection leakage at the threaded joint is not the same as valve seat leakage, simmer or set-pressure error. If leakage is observed, the inspection should distinguish between thread fit, sealant or gasket condition, installation stress, seat damage, set pressure behavior and service contamination before deciding on replacement. For seat-leakage testing context, review ZOBAI\u2019s <a href=\"https:\/\/zobai.com\/standards\/api-527-seat-tightness-test\/\">API 527 seat tightness test<\/a> guide.<\/p>\n\n  <h3>Thread verification workflow<\/h3>\n  <div class=\"zobai-process\">\n    <div class=\"zobai-process-step\">\n      <strong>Identify visible markings<\/strong>\n      <span>Collect nameplate, body marking, old datasheet and any project drawing.<\/span>\n    <\/div>\n    <div class=\"zobai-process-step\">\n      <strong>Confirm thread form<\/strong>\n      <span>Check NPT, BSP, G, Rc or other project-defined thread using reliable evidence.<\/span>\n    <\/div>\n    <div class=\"zobai-process-step\">\n      <strong>Confirm connection details<\/strong>\n      <span>Record thread size, male\/female connection, inlet\/outlet arrangement and sealing method.<\/span>\n    <\/div>\n    <div class=\"zobai-process-step\">\n      <strong>Verify valve duty<\/strong>\n      <span>Do not finalize replacement until set pressure, capacity, medium and material are checked.<\/span>\n    <\/div>\n  <\/div>\n\n  <div class=\"zobai-table-wrap\" role=\"region\" aria-label=\"Thread type confirmation checklist\" tabindex=\"0\">\n    <table class=\"zobai-table\">\n      <thead>\n        <tr>\n          <th>Thread Question<\/th>\n          <th>Buyer Should Provide<\/th>\n          <th>Why It Is Needed<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>What thread type is required?<\/td>\n          <td>NPT, BSP, G, Rc or project drawing.<\/td>\n          <td>Prevents incompatible connection selection.<\/td>\n        <\/tr>\n        <tr>\n          <td>Is the connection male or female?<\/td>\n          <td>Inlet and outlet gender.<\/td>\n          <td>Prevents installation mismatch.<\/td>\n        <\/tr>\n        <tr>\n          <td>How does the connection seal?<\/td>\n          <td>Thread seal, gasket, sealing face or project method.<\/td>\n          <td>Separates connection leakage from seat leakage.<\/td>\n        <\/tr>\n        <tr>\n          <td>Is this a replacement?<\/td>\n          <td>Existing valve photos, nameplate and old datasheet if available.<\/td>\n          <td>Supports interchangeability review beyond thread size.<\/td>\n        <\/tr>\n        <tr>\n          <td>Is the existing thread damaged or uncertain?<\/td>\n          <td>Close-up photos, thread gauge result or maintenance note.<\/td>\n          <td>Prevents repeating a failed or damaged installation condition.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<section class=\"zobai-section\" id=\"pressure-capacity\">\n  <h2>Pressure and Capacity Terms Must Not Be Mixed<\/h2>\n  <p>Threaded safety valve selection often fails when buyers treat thread size, set pressure and capacity as if they describe the same thing. They do not. The threaded connection defines how the valve connects to equipment or piping. It does not define the required relieving load or the selected valve capacity basis.<\/p>\n\n  <div class=\"zobai-table-wrap\" role=\"region\" aria-label=\"Pressure and capacity terms for threaded safety valves\" tabindex=\"0\">\n    <table class=\"zobai-table\">\n      <thead>\n        <tr>\n          <th>Term<\/th>\n          <th>What It Means<\/th>\n          <th>Why It Matters for Threaded Safety Valves<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>Operating pressure<\/td>\n          <td>Normal pressure during operation.<\/td>\n          <td>Shows operating margin below set pressure and risk of simmer or leakage.<\/td>\n        <\/tr>\n        <tr>\n          <td>MAWP \/ design pressure<\/td>\n          <td>Pressure basis of the protected equipment or system design.<\/td>\n          <td>Defines pressure-protection boundary and must not be replaced by thread rating alone.<\/td>\n        <\/tr>\n        <tr>\n          <td>Set pressure<\/td>\n          <td>Pressure at which the valve is adjusted to begin opening under specified conditions.<\/td>\n          <td>Defines opening point, not the required relieving capacity.<\/td>\n        <\/tr>\n        <tr>\n          <td>Required relieving capacity<\/td>\n          <td>Flow rate required to control the governing relief scenario.<\/td>\n          <td>Must be calculated or specified from the relief case; thread size alone is not enough.<\/td>\n        <\/tr>\n        <tr>\n          <td>Selected valve capacity basis<\/td>\n          <td>Manufacturer-supported or documented capacity basis for the selected valve.<\/td>\n          <td>Must match the actual medium, pressure, temperature and back pressure conditions.<\/td>\n        <\/tr>\n        <tr>\n          <td>Pressure-temperature rating<\/td>\n          <td>Allowable pressure limit of material\/connection at temperature, depending on the applicable rating basis.<\/td>\n          <td>Threaded connection and body material must be checked against service temperature and project specification.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"zobai-callout\" role=\"note\">\n    <p><strong>Capacity caution:<\/strong> A 1\/2 inch, 3\/4 inch or 1 inch thread does not prove required relieving capacity. The governing relief scenario, fluid properties, relieving pressure, relieving temperature and back pressure must still be reviewed. For standards-focused sizing context, review ZOBAI\u2019s <a href=\"https:\/\/zobai.com\/standards\/api-520-safety-valve-sizing\/\">API 520 safety valve sizing<\/a> guide.<\/p>\n  <\/div>\n<\/section>\n\n<section class=\"zobai-section\" id=\"applications\">\n  <h2>Where Are Threaded Safety Valves Commonly Used?<\/h2>\n  <p>Threaded safety valves are often considered where the equipment connection or piping system uses threaded ports and where the required capacity, pressure rating, service condition and project specification allow a threaded connection.<\/p>\n\n  <div class=\"zobai-grid\">\n    <div class=\"zobai-card\">\n      <h3>Compact skids and OEM equipment<\/h3>\n      <p>Threaded valves may be used where space, piping layout and equipment ports are already defined by a skid or OEM design.<\/p>\n    <\/div>\n    <div class=\"zobai-card\">\n      <h3>Small vessels and utility systems<\/h3>\n      <p>They may be considered for selected air, gas, water, steam or auxiliary systems when threaded piping is specified.<\/p>\n    <\/div>\n    <div class=\"zobai-card\">\n      <h3>Replacement and distributor applications<\/h3>\n      <p>Distributors often receive old valve photos or partial nameplate data, but replacement must not rely on appearance alone.<\/p>\n    <\/div>\n  <\/div>\n\n  <h3>Preliminary selection matrix<\/h3>\n  <div class=\"zobai-table-wrap\" role=\"region\" aria-label=\"Preliminary threaded safety valve selection matrix\" tabindex=\"0\">\n    <table class=\"zobai-table\">\n      <thead>\n        <tr>\n          <th>Condition<\/th>\n          <th>Why Threaded May Be Reviewed<\/th>\n          <th>Data Still Needed<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>Equipment has a threaded port<\/td>\n          <td>The connection may match the equipment interface.<\/td>\n          <td>Thread form, size, gender, sealing method, pressure rating and service duty.<\/td>\n        <\/tr>\n        <tr>\n          <td>Compact skid or OEM package<\/td>\n          <td>Threaded connection may fit limited space and package piping.<\/td>\n          <td>Relief scenario, required capacity, vibration, discharge route and maintenance access.<\/td>\n        <\/tr>\n        <tr>\n          <td>Distributor replacement inquiry<\/td>\n          <td>Threaded valves are often replaced from existing photos or partial records.<\/td>\n          <td>Nameplate, old datasheet, thread evidence, medium, set pressure and capacity basis.<\/td>\n        <\/tr>\n        <tr>\n          <td>Utility air, gas, water or steam service<\/td>\n          <td>Threaded connection may be used where project specification allows.<\/td>\n          <td>Medium\/phase, temperature, material, seat\/seal, discharge safety and documents.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"zobai-callout\" role=\"note\">\n    <p><strong>Engineering boundary:<\/strong> Convenience is not a selection basis. Capacity, pressure rating, temperature, back pressure, materials and discharge safety remain necessary.<\/p>\n  <\/div>\n<\/section>\n\n<section class=\"zobai-section\" id=\"limits\">\n  <h2>When a Threaded Safety Valve May Not Be Suitable<\/h2>\n  <p>A threaded safety valve may not be suitable when the required relieving load, piping specification, vibration, maintenance practice, pressure-temperature condition or project documentation requires another connection type.<\/p>\n\n  <h3>Capacity and pressure-rating limits<\/h3>\n  <p>Threaded connection size does not prove relieving capacity. A buyer should not assume that a larger thread automatically means sufficient capacity or that a same-size threaded replacement will pass the same flow. For capacity-related decisions, review <a href=\"https:\/\/zobai.com\/blog\/safety-valve-sizing-and-certified-relieving-capacity-guide\/\">safety valve sizing and certified capacity<\/a>.<\/p>\n\n  <h3>Vibration, maintenance and outlet piping<\/h3>\n  <p>Threaded connections can be sensitive to installation quality, repeated removal, vibration, sealant practice and piping stress. If the equipment vibrates, the outlet piping is heavy, or the valve must be frequently removed for inspection, the connection and installation should be reviewed carefully.<\/p>\n\n  <h3>When a flanged connection may be reviewed<\/h3>\n  <p>A <a href=\"https:\/\/zobai.com\/safety-valves\/flanged-safety-valves\/\">flanged safety valve<\/a> may be reviewed when the system requires easier removal, larger connection size, heavier piping, formal piping-class alignment, higher documentation expectations or a project specification that calls for flanged connections.<\/p>\n\n  <div class=\"zobai-grid zobai-grid-2\">\n    <div class=\"zobai-card\">\n      <h3>Review threaded carefully when<\/h3>\n      <ul class=\"zobai-checklist\">\n        <li>The required relieving capacity is not yet calculated or documented.<\/li>\n        <li>The outlet line is heavy, vibrating, restricted or connected to a header.<\/li>\n        <li>The thread form is uncertain or the old valve is damaged.<\/li>\n        <li>The medium is corrosive, dirty, high-temperature, freezing or polymerizing.<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"zobai-card zobai-card-caution\">\n      <h3>Do not assume<\/h3>\n      <ul class=\"zobai-checklist\">\n        <li>Do not assume thread size proves capacity.<\/li>\n        <li>Do not assume NPT, BSP, G and Rc are interchangeable.<\/li>\n        <li>Do not assume stainless steel or brass automatically suits the medium.<\/li>\n        <li>Do not assume a standard name proves final compliance.<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"zobai-section\" id=\"threaded-vs-flanged\">\n  <h2>Threaded Safety Valve vs Flanged Safety Valve<\/h2>\n  <p>The difference between a threaded safety valve and a flanged safety valve is mainly the end connection. Both may serve pressure relief functions, but installation, maintenance, documentation and piping interface can be different.<\/p>\n\n  <figure class=\"zobai-figure\" data-image-status=\"planned\" data-image-slot=\"image-04-threaded-vs-flanged-boundary\">\n    <img loading=\"lazy\" class=\"zobai-figure-img\" src=\"https:\/\/zobai.com\/wp-content\/uploads\/2026\/06\/threaded-vs-flanged-safety-valve-connection-boundary.webp\" alt=\"Comparison visual showing threaded safety valve and flanged safety valve connection selection boundary\" title=\"Threaded vs flanged safety valve connection boundary\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\">\n    <figcaption>Threaded and flanged safety valves are reviewed by connection type, capacity, piping, maintenance and project specification.<\/figcaption>\n    <p class=\"zobai-figure-note\">AI-generated selection-boundary illustration, not a universal ranking of connection types.<\/p>\n  <\/figure>\n\n  <div class=\"zobai-table-wrap\" role=\"region\" aria-label=\"Threaded versus flanged safety valve decision table\" tabindex=\"0\">\n    <table class=\"zobai-table\">\n      <thead>\n        <tr>\n          <th>Selection Factor<\/th>\n          <th>Threaded Safety Valve<\/th>\n          <th>Flanged Safety Valve<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>Typical connection<\/td>\n          <td>Screwed connection.<\/td>\n          <td>Bolted flange connection.<\/td>\n        <\/tr>\n        <tr>\n          <td>Common use<\/td>\n          <td>Compact equipment, skids, small vessels and utility systems.<\/td>\n          <td>Larger piping systems, formal process lines and heavier outlet piping.<\/td>\n        <\/tr>\n        <tr>\n          <td>Capacity assumption<\/td>\n          <td>Thread size does not prove capacity.<\/td>\n          <td>Flange size does not prove capacity.<\/td>\n        <\/tr>\n        <tr>\n          <td>Maintenance<\/td>\n          <td>Requires thread and sealing review during removal and reinstallation.<\/td>\n          <td>Often easier to remove and reinstall in piping systems.<\/td>\n        <\/tr>\n        <tr>\n          <td>Project specification<\/td>\n          <td>Suitable only if allowed by project requirements.<\/td>\n          <td>Often specified by piping class or project standard.<\/td>\n        <\/tr>\n        <tr>\n          <td>Documentation<\/td>\n          <td>Must still confirm datasheet, material, test and capacity basis.<\/td>\n          <td>May align more directly with piping class and flange standard documentation.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<section class=\"zobai-section\" id=\"engineering-checks\">\n  <h2>Engineering Checks Before Selecting a Threaded Safety Valve<\/h2>\n  <p>Before selecting a threaded safety valve, review the connection as part of the full pressure-protection system. The valve, inlet path, outlet path, sealing method, medium, capacity basis and documents all affect the decision.<\/p>\n\n  <h3>Back pressure and outlet piping review<\/h3>\n  <div class=\"zobai-table-wrap\" role=\"region\" aria-label=\"Back pressure and outlet piping review table\" tabindex=\"0\">\n    <table class=\"zobai-table\">\n      <thead>\n        <tr>\n          <th>Item<\/th>\n          <th>What to Check<\/th>\n          <th>Why It Matters<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>Threaded inlet path<\/td>\n          <td>Thread engagement, sealant position, upstream restriction and inlet pressure loss.<\/td>\n          <td>Excessive restriction or sealant intrusion can affect valve opening behavior, stability and capacity review.<\/td>\n        <\/tr>\n        <tr>\n          <td>Superimposed back pressure<\/td>\n          <td>Outlet pressure already present before the valve opens.<\/td>\n          <td>May affect opening behavior, capacity or selected configuration.<\/td>\n        <\/tr>\n        <tr>\n          <td>Built-up back pressure<\/td>\n          <td>Pressure created in outlet piping during relieving flow.<\/td>\n          <td>May reduce capacity or create instability if discharge path is restricted.<\/td>\n        <\/tr>\n        <tr>\n          <td>Outlet piping load<\/td>\n          <td>Pipe weight, vibration, thermal movement and support.<\/td>\n          <td>A threaded outlet should not be used as structural support for heavy piping.<\/td>\n        <\/tr>\n        <tr>\n          <td>Discharge direction<\/td>\n          <td>Safe venting, drainage and routing away from personnel or equipment hazards.<\/td>\n          <td>Threaded connection does not remove the need for safe discharge design.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p>For deeper back-pressure terminology and balanced-bellows context, review ZOBAI\u2019s <a href=\"https:\/\/zobai.com\/engineering\/back-pressure-and-bellows\/\">back pressure and bellows guide<\/a>.<\/p>\n\n  <h3>Medium and material screening<\/h3>\n  <div class=\"zobai-table-wrap\" role=\"region\" aria-label=\"Medium and material screening table\" tabindex=\"0\">\n    <table class=\"zobai-table\">\n      <thead>\n        <tr>\n          <th>Service Condition<\/th>\n          <th>Main Risk<\/th>\n          <th>What to Confirm<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>Steam or high-temperature service<\/td>\n          <td>Seat, spring, gasket and body material may be temperature-limited.<\/td>\n          <td>Relieving temperature, material rating, bonnet\/cap arrangement and discharge condition.<\/td>\n        <\/tr>\n        <tr>\n          <td>Corrosive medium<\/td>\n          <td>Body, trim, spring, thread area and seal may corrode differently.<\/td>\n          <td>Medium composition, concentration, temperature and material compatibility.<\/td>\n        <\/tr>\n        <tr>\n          <td>Dirty or particle-containing service<\/td>\n          <td>Seat damage, leakage or blocked flow path may occur.<\/td>\n          <td>Fluid cleanliness, filtration, maintenance access and seat material.<\/td>\n        <\/tr>\n        <tr>\n          <td>Liquid or two-phase service<\/td>\n          <td>Sizing and discharge behavior differ from gas\/vapor service.<\/td>\n          <td>Phase, density, viscosity, back pressure and relief scenario basis.<\/td>\n        <\/tr>\n        <tr>\n          <td>Freezing or outdoor service<\/td>\n          <td>Threaded connection, outlet or drain path may freeze or restrict discharge.<\/td>\n          <td>Ambient condition, insulation, drainage, orientation and material suitability.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3>Installation do \/ do-not checklist<\/h3>\n  <div class=\"zobai-grid zobai-grid-2\">\n    <div class=\"zobai-card\">\n      <h3>Do<\/h3>\n      <ul class=\"zobai-checklist\">\n        <li>Confirm thread form, size, gender and sealing method before installation.<\/li>\n        <li>Keep the inlet path short, clean and consistent with the project pressure-loss basis.<\/li>\n        <li>Support outlet piping so the valve body is not carrying pipe weight.<\/li>\n        <li>Confirm safe discharge, drainage and maintenance access.<\/li>\n        <li>Record nameplate, datasheet and test documentation for replacement history.<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"zobai-card zobai-card-caution\">\n      <h3>Do not<\/h3>\n      <ul class=\"zobai-checklist\">\n        <li>Do not force mismatched threads to fit.<\/li>\n        <li>Do not use excessive sealant that may enter the flow path.<\/li>\n        <li>Do not select by thread size and set pressure only.<\/li>\n        <li>Do not ignore vibration, outlet load or repeated removal.<\/li>\n        <li>Do not claim compliance without selected model and document review.<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n\n  <p>For broader inlet\/outlet piping and discharge considerations, review the <a href=\"https:\/\/zobai.com\/engineering\/safety-valve-installation-guide\/\">safety valve installation guide<\/a>.<\/p>\n<\/section>\n\n<section class=\"zobai-section\" id=\"rfq-data\">\n  <h2>Selection Data Required Before RFQ<\/h2>\n  <p>A threaded safety valve inquiry should include both pressure-relief data and connection data. Without both, the quotation may be incomplete or technically unsafe.<\/p>\n\n  <figure class=\"zobai-figure\" data-image-status=\"planned\" data-image-slot=\"image-05-threaded-safety-valve-rfq-checklist\">\n    <img loading=\"lazy\" class=\"zobai-figure-img\" src=\"https:\/\/zobai.com\/wp-content\/uploads\/2026\/06\/threaded-safety-valve-rfq-checklist.webp\" alt=\"RFQ checklist for threaded safety valve selection including thread type, pressure, capacity, medium and documents\" title=\"Threaded safety valve RFQ checklist\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\">\n    <figcaption>A threaded safety valve inquiry should include both pressure-relief data and connection data.<\/figcaption>\n    <p class=\"zobai-figure-note\">AI-generated RFQ illustration. A quotation or replacement review should not be based only on thread size, set pressure or photos.<\/p>\n  <\/figure>\n\n  <div class=\"zobai-table-wrap\" role=\"region\" aria-label=\"Threaded safety valve RFQ data table\" tabindex=\"0\">\n    <table class=\"zobai-table\">\n      <thead>\n        <tr>\n          <th>Data Group<\/th>\n          <th>Required Input<\/th>\n          <th>Why It Matters<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>Protected equipment<\/td>\n          <td>Vessel, tank, skid, compressor, pipeline, utility system or OEM equipment.<\/td>\n          <td>Defines the protected system and design basis.<\/td>\n        <\/tr>\n        <tr>\n          <td>Relief scenario<\/td>\n          <td>Blocked outlet, fire case, thermal expansion, regulator failure or other case.<\/td>\n          <td>Determines required relieving load.<\/td>\n        <\/tr>\n        <tr>\n          <td>Pressure data<\/td>\n          <td>Operating pressure, MAWP\/design pressure, set pressure and allowable overpressure basis.<\/td>\n          <td>Prevents pressure-definition errors.<\/td>\n        <\/tr>\n        <tr>\n          <td>Capacity data<\/td>\n          <td>Required relieving rate, fluid properties and capacity basis.<\/td>\n          <td>Prevents selection by thread size only.<\/td>\n        <\/tr>\n        <tr>\n          <td>Thread data<\/td>\n          <td>Thread type, size, male\/female connection, inlet\/outlet details and sealing method.<\/td>\n          <td>Prevents mismatch during ordering or replacement.<\/td>\n        <\/tr>\n        <tr>\n          <td>Back pressure and piping<\/td>\n          <td>Outlet pressure, discharge route, pipe support, restriction and drainage.<\/td>\n          <td>Affects capacity, stability, leakage and safe discharge.<\/td>\n        <\/tr>\n        <tr>\n          <td>Materials\/documents<\/td>\n          <td>Body, trim, seat, seal, spring, certificates, tests and inspection scope.<\/td>\n          <td>Supports procurement and compliance review.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3>Test and documentation matrix<\/h3>\n  <div class=\"zobai-table-wrap\" role=\"region\" aria-label=\"Threaded safety valve test and documentation matrix\" tabindex=\"0\">\n    <table class=\"zobai-table\">\n      <thead>\n        <tr>\n          <th>Document \/ Check<\/th>\n          <th>What It Supports<\/th>\n          <th>What It Does Not Prove Alone<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>Datasheet<\/td>\n          <td>Model, size, connection, set pressure, material and service basis.<\/td>\n          <td>Does not replace relief calculation or project approval.<\/td>\n        <\/tr>\n        <tr>\n          <td>Nameplate<\/td>\n          <td>Identification and key valve information.<\/td>\n          <td>Does not prove interchangeability if capacity, thread form or material are unclear.<\/td>\n        <\/tr>\n        <tr>\n          <td>Set pressure test<\/td>\n          <td>Opening pressure under specified test conditions.<\/td>\n          <td>Does not prove required relieving capacity.<\/td>\n        <\/tr>\n        <tr>\n          <td>Seat tightness test<\/td>\n          <td>Leakage performance against a defined test method and acceptance basis.<\/td>\n          <td>Does not prove the thread connection will not leak if installed incorrectly.<\/td>\n        <\/tr>\n        <tr>\n          <td>Material records<\/td>\n          <td>Traceability for specified parts where required.<\/td>\n          <td>Does not prove service compatibility without medium and temperature review.<\/td>\n        <\/tr>\n        <tr>\n          <td>Capacity basis<\/td>\n          <td>Whether selected valve can pass the required relieving load.<\/td>\n          <td>Must still match actual medium, relieving pressure, temperature and back pressure.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <p>For pressure-temperature context, review ZOBAI\u2019s <a href=\"https:\/\/zobai.com\/standards\/pressure-temperature-ratings\/\">pressure-temperature ratings<\/a> guide. For broader terminology differences, review <a href=\"https:\/\/zobai.com\/blog\/prv-vs-psv-vs-safety-valve-vs-relief-valve\/\">PRV vs PSV vs safety valve vs relief valve<\/a>.<\/p>\n<\/section>\n\n<section class=\"zobai-section\" id=\"mistakes\">\n  <h2>Common Mistakes When Buying or Replacing Threaded Safety Valves<\/h2>\n  <p>Threaded safety valve mistakes often happen because the visible connection is easy to identify while the pressure-protection function is harder to verify.<\/p>\n\n  <div class=\"zobai-table-wrap\" role=\"region\" aria-label=\"Common threaded safety valve mistakes matrix\" tabindex=\"0\">\n    <table class=\"zobai-table\">\n      <thead>\n        <tr>\n          <th>Mistake<\/th>\n          <th>Why It Is Risky<\/th>\n          <th>Correct Check<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>Selecting by thread size only<\/td>\n          <td>Same thread size may not mean same capacity or construction.<\/td>\n          <td>Confirm thread type, set pressure, capacity, material and documents.<\/td>\n        <\/tr>\n        <tr>\n          <td>Confusing NPT\/BSP\/G\/Rc<\/td>\n          <td>Similar appearance may hide different thread forms.<\/td>\n          <td>Confirm exact thread standard, gender and sealing method.<\/td>\n        <\/tr>\n        <tr>\n          <td>Ignoring capacity<\/td>\n          <td>Thread size is not orifice area.<\/td>\n          <td>Confirm required relieving capacity and selected valve capacity basis.<\/td>\n        <\/tr>\n        <tr>\n          <td>Ignoring medium<\/td>\n          <td>Material and seat may be unsuitable.<\/td>\n          <td>Confirm medium, phase, temperature and corrosion risk.<\/td>\n        <\/tr>\n        <tr>\n          <td>Ignoring outlet piping<\/td>\n          <td>Discharge may create back pressure, vibration or mechanical load.<\/td>\n          <td>Confirm outlet route, support, drainage and safe discharge.<\/td>\n        <\/tr>\n        <tr>\n          <td>Replacing by appearance<\/td>\n          <td>Similar-looking valves may not be interchangeable.<\/td>\n          <td>Check nameplate, datasheet, thread form and service data.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<section class=\"zobai-section\" id=\"replacement-workflow\">\n  <h2>Replacement Verification Workflow<\/h2>\n  <p>For a replacement inquiry, the safest workflow is to verify both the connection and the pressure-protection duty. A clear photo can help, but it cannot replace set pressure, capacity, material and service data.<\/p>\n\n  <div class=\"zobai-process\">\n    <div class=\"zobai-process-step\">\n      <strong>Collect existing evidence<\/strong>\n      <span>Send full valve photos, nameplate, inlet\/outlet thread close-ups, installation photos and old datasheet if available.<\/span>\n    <\/div>\n    <div class=\"zobai-process-step\">\n      <strong>Confirm connection<\/strong>\n      <span>Verify thread type, size, male\/female connection, sealing method and any damaged thread condition.<\/span>\n    <\/div>\n    <div class=\"zobai-process-step\">\n      <strong>Confirm duty<\/strong>\n      <span>Review protected equipment, relief scenario, set pressure, MAWP\/design pressure and required capacity.<\/span>\n    <\/div>\n    <div class=\"zobai-process-step\">\n      <strong>Confirm documents<\/strong>\n      <span>Check material records, test requirements, capacity basis, inspection scope and project specification.<\/span>\n    <\/div>\n  <\/div>\n\n  <h3>Composite engineering scenarios for training<\/h3>\n  <p>The following examples are composite engineering scenarios for training. They do not describe a real customer project, product proof, certified capacity test, accident record or guaranteed ZOBAI model capability.<\/p>\n\n  <div class=\"zobai-grid\">\n    <div class=\"zobai-card\">\n      <h3>Compact air receiver replacement<\/h3>\n      <p>A buyer sends an old threaded safety valve photo from an air receiver, but the nameplate is unclear. ZOBAI would still need set pressure, receiver MAWP\/design pressure, required capacity, thread type, medium, temperature and outlet arrangement.<\/p>\n    <\/div>\n    <div class=\"zobai-card\">\n      <h3>Vibrating compressor package<\/h3>\n      <p>A threaded valve may fit the port, but vibration, outlet support, inlet pressure loss and maintenance access may change the connection decision.<\/p>\n    <\/div>\n    <div class=\"zobai-card\">\n      <h3>BSP\/NPT replacement confusion<\/h3>\n      <p>A distributor requests a same-size threaded valve, but the old equipment may use a different thread form. Thread standard and sealing method must be verified before quotation.<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"zobai-section zobai-rfq\" id=\"zobai-review\">\n  <h2>What ZOBAI Needs to Review a Threaded Safety Valve Inquiry<\/h2>\n  <p>For a new threaded safety valve inquiry, send the protected equipment, relief scenario, medium and phase, operating pressure, MAWP or design pressure, set pressure, required relieving capacity, relieving temperature, back pressure, inlet and outlet thread details, material requirements, applicable standard and required documents.<\/p>\n  <p>For a replacement inquiry, also send photos of the existing valve, nameplate, inlet thread, outlet thread, installation position and surrounding piping. If the old datasheet is available, include it.<\/p>\n  <ul class=\"zobai-checklist\">\n    <li>Protected equipment and governing relief scenario<\/li>\n    <li>Medium, phase, operating pressure, MAWP\/design pressure and set pressure<\/li>\n    <li>Required relieving capacity and capacity basis<\/li>\n    <li>Relieving temperature and back pressure<\/li>\n    <li>Thread type, thread size, male\/female connection and sealing method<\/li>\n    <li>Body, trim, seat, seal, spring, standard and document requirements<\/li>\n    <li>Existing datasheet, nameplate and installation photos for replacement<\/li>\n  <\/ul>\n  <div class=\"zobai-hero-actions\">\n    <a class=\"zobai-btn zobai-btn-secondary\" href=\"https:\/\/zobai.com\/ask-an-engineer\/\">Ask a Safety Valve Engineer<\/a>\n    <a class=\"zobai-btn zobai-btn-secondary\" href=\"https:\/\/zobai.com\/contacts\/\">Contact ZOBAI for RFQ<\/a>\n  <\/div>\n<\/section>\n\n<section class=\"zobai-section\" id=\"faq\">\n  <h2>FAQ About Threaded Safety Valves<\/h2>\n\n  <div class=\"zobai-faq\">\n    <h3>What does threaded safety valve mean?<\/h3>\n    <p>A threaded safety valve is a safety valve or pressure relief valve with threaded end connections. The threaded connection may be used at the inlet, outlet or both, depending on the selected valve and piping arrangement.<\/p>\n  <\/div>\n\n  <div class=\"zobai-faq\">\n    <h3>Is a threaded safety valve the same as a threaded pressure relief valve?<\/h3>\n    <p>The terms may overlap in buyer communication, but exact terminology depends on service, code context and regional usage. The important point is to confirm the safety function, protected equipment, relief scenario, set pressure, required capacity and connection details.<\/p>\n  <\/div>\n\n  <div class=\"zobai-faq\">\n    <h3>Can I replace a threaded safety valve by thread size only?<\/h3>\n    <p>No. Thread size alone does not prove thread form, set pressure, capacity, material, seat design, spring design, pressure rating or documentation. Replacement should be checked against the original datasheet, nameplate and service conditions.<\/p>\n  <\/div>\n\n  <div class=\"zobai-faq\">\n    <h3>What is the difference between NPT and BSP threaded safety valves?<\/h3>\n    <p>NPT and BSP are different thread forms and should not be assumed interchangeable by appearance. For replacement or RFQ, confirm the exact thread standard, size, male\/female connection and sealing method.<\/p>\n  <\/div>\n\n  <div class=\"zobai-faq\">\n    <h3>When should I choose flanged instead of threaded?<\/h3>\n    <p>A flanged connection may be reviewed when the system requires larger capacity, heavier piping, easier removal, formal piping-class alignment, higher documentation requirements or a project specification that requires flanged valves.<\/p>\n  <\/div>\n\n  <div class=\"zobai-faq\">\n    <h3>Does thread size determine relieving capacity?<\/h3>\n    <p>No. Thread size does not determine relieving capacity. Required capacity depends on the relief scenario, fluid properties, relieving pressure, temperature, back pressure and selected valve capacity basis.<\/p>\n  <\/div>\n\n  <div class=\"zobai-faq\">\n    <h3>What information should I send before RFQ?<\/h3>\n    <p>Send protected equipment, relief scenario, medium and phase, operating pressure, MAWP\/design pressure, set pressure, required relieving capacity, relieving temperature, back pressure, thread type, thread size, male\/female connection, material requirements, standards and documents.<\/p>\n  <\/div>\n\n  <div class=\"zobai-faq\">\n    <h3>Can threaded safety valves be used for steam, gas or liquid?<\/h3>\n    <p>They may be used in selected steam, gas or liquid services, depending on valve design and project requirements. The medium, phase, pressure, temperature, capacity, seat\/seal material and discharge arrangement must be confirmed before selection.<\/p>\n  <\/div>\n<\/section>\n\n<section class=\"zobai-section zobai-note\" id=\"technical-references\">\n  <h2>Technical References<\/h2>\n  <p>The following references support sizing, selection and pressure relief device testing context. They are used for engineering background only and do not prove that any specific ZOBAI threaded safety valve model is certified, approved or suitable for a specific project.<\/p>\n  <ul class=\"zobai-reference-list\">\n    <li><a href=\"https:\/\/www.api.org\/products-and-services\/standards\/important-standards-announcements\/520parti\" target=\"_blank\" rel=\"noopener noreferrer\">API 520 Part I: Sizing, Selection, and Installation of Pressure-Relieving Devices in Refineries<\/a> <span>\u2014 supports pressure-relieving device sizing and selection context.<\/span><\/li>\n    <li><a href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/pressure-relief-devices\" target=\"_blank\" rel=\"noopener noreferrer\">ASME PTC 25: Pressure Relief Devices<\/a> <span>\u2014 supports pressure relief device performance and testing context.<\/span><\/li>\n  <\/ul>\n<\/section>\n\n<section class=\"zobai-section zobai-note\" id=\"standards-note\">\n  <h2>Standards and Engineering Limitation Note<\/h2>\n  <p>Threaded safety valve selection may involve thread standards, pressure-temperature ratings, valve testing, material records, inspection requirements and project-specific documentation. A standard name or thread name alone does not complete the valve specification.<\/p>\n  <p>Final selection depends on real service conditions, governing relief scenario, selected manufacturer data, applicable standard version, project specification and local regulatory requirements. This article is for engineering communication and RFQ preparation; it does not replace formal relief sizing, selected model datasheets, capacity verification, applicable code review or project authority approval.<\/p>\n<\/section>\n\n<section class=\"zobai-section zobai-note\" id=\"technical-review\">\n  <h2>Technical Review Note<\/h2>\n  <p>This article is prepared for procurement buyers, replacement users, maintenance teams and engineers who need to understand threaded safety valve connection requirements before quotation or replacement. It does not claim that every threaded safety valve is suitable for every medium, pressure, temperature, capacity or jurisdiction.<\/p>\n  <p class=\"zobai-muted\">Reviewed topics: threaded connection definition, NPT\/BSP\/G\/Rc mismatch, pressure terminology, capacity boundary, back pressure, materials, installation, test documents, replacement workflow and RFQ data.<\/p>\n<\/section>\n\n<section class=\"zobai-section zobai-related\" id=\"related-pages\">\n  <h2>Related ZOBAI Pages<\/h2>\n  <ul>\n    <li><a href=\"https:\/\/zobai.com\/safety-valves\/threaded-safety-valves\/\">Threaded safety valves<\/a><\/li>\n    <li><a href=\"https:\/\/zobai.com\/safety-valves\/flanged-safety-valves\/\">Flanged safety valves<\/a><\/li>\n    <li><a href=\"https:\/\/zobai.com\/blog\/safety-valve-sizing-and-certified-relieving-capacity-guide\/\">Safety valve sizing and certified capacity<\/a><\/li>\n    <li><a href=\"https:\/\/zobai.com\/engineering\/safety-valve-installation-guide\/\">Safety valve installation guide<\/a><\/li>\n    <li><a href=\"https:\/\/zobai.com\/engineering\/back-pressure-and-bellows\/\">Back pressure and bellows guide<\/a><\/li>\n    <li><a href=\"https:\/\/zobai.com\/standards\/api-527-seat-tightness-test\/\">API 527 seat tightness test<\/a><\/li>\n  <\/ul>\n<\/section>\n\n  <\/div>\n<\/article>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@graph\":[\n    {\n      \"@type\":\"TechArticle\",\n      \"@id\":\"https:\/\/zobai.com\/blog\/what-is-a-threaded-safety-valve\/#article\",\n      \"headline\":\"What Is a Threaded Safety Valve?\",\n      \"description\":\"Learn what a threaded safety valve is, how NPT, BSP, G and Rc threads affect selection, when threaded connections are suitable, and what RFQ data buyers must confirm.\",\n      \"mainEntityOfPage\":{\n        \"@type\":\"WebPage\",\n        \"@id\":\"https:\/\/zobai.com\/blog\/what-is-a-threaded-safety-valve\/\"\n      },\n      \"image\":[\n        \"https:\/\/zobai.com\/wp-content\/uploads\/2026\/06\/threaded-safety-valve-overview.webp\",\n        \"https:\/\/zobai.com\/wp-content\/uploads\/2026\/06\/threaded-safety-valve-connection-close-up.webp\",\n        \"https:\/\/zobai.com\/wp-content\/uploads\/2026\/06\/threaded-safety-valve-thread-type-confirmation.webp\",\n        \"https:\/\/zobai.com\/wp-content\/uploads\/2026\/06\/threaded-vs-flanged-safety-valve-connection-boundary.webp\",\n        \"https:\/\/zobai.com\/wp-content\/uploads\/2026\/06\/threaded-safety-valve-rfq-checklist.webp\"\n      ],\n      \"author\":{\n        \"@type\":\"Organization\",\n        \"name\":\"ZOBAI Valve Co., Ltd.\",\n        \"url\":\"https:\/\/zobai.com\/about-us\/\"\n      },\n      \"publisher\":{\n        \"@type\":\"Organization\",\n        \"name\":\"ZOBAI Valve Co., Ltd.\",\n        \"url\":\"https:\/\/zobai.com\/\"\n      },\n      \"about\":[\n        \"threaded safety valve\",\n        \"threaded pressure relief valve\",\n        \"NPT safety valve\",\n        \"BSP safety valve\",\n        \"safety valve RFQ data\"\n      ],\n      \"citation\":[\n        \"https:\/\/www.api.org\/products-and-services\/standards\/important-standards-announcements\/520parti\",\n        \"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/pressure-relief-devices\"\n      ],\n      \"inLanguage\":\"en\"\n    },\n    {\n      \"@type\":\"FAQPage\",\n      \"@id\":\"https:\/\/zobai.com\/blog\/what-is-a-threaded-safety-valve\/#faq\",\n      \"mainEntity\":[\n        {\n          \"@type\":\"Question\",\n          \"name\":\"What does threaded safety valve mean?\",\n          \"acceptedAnswer\":{\n            \"@type\":\"Answer\",\n            \"text\":\"A threaded safety valve is a safety valve or pressure relief valve with threaded end connections. The threaded connection may be used at the inlet, outlet or both, depending on the selected valve and piping arrangement.\"\n          }\n        },\n        {\n          \"@type\":\"Question\",\n          \"name\":\"Is a threaded safety valve the same as a threaded pressure relief valve?\",\n          \"acceptedAnswer\":{\n            \"@type\":\"Answer\",\n            \"text\":\"The terms may overlap in buyer communication, but exact terminology depends on service, code context and regional usage. The important point is to confirm the safety function, protected equipment, relief scenario, set pressure, required capacity and connection details.\"\n          }\n        },\n        {\n          \"@type\":\"Question\",\n          \"name\":\"Can I replace a threaded safety valve by thread size only?\",\n          \"acceptedAnswer\":{\n            \"@type\":\"Answer\",\n            \"text\":\"No. Thread size alone does not prove thread form, set pressure, capacity, material, seat design, spring design, pressure rating or documentation. Replacement should be checked against the original datasheet, nameplate and service conditions.\"\n          }\n        },\n        {\n          \"@type\":\"Question\",\n          \"name\":\"What is the difference between NPT and BSP threaded safety valves?\",\n          \"acceptedAnswer\":{\n            \"@type\":\"Answer\",\n            \"text\":\"NPT and BSP are different thread forms and should not be assumed interchangeable by appearance. For replacement or RFQ, confirm the exact thread standard, size, male or female connection and sealing method.\"\n          }\n        },\n        {\n          \"@type\":\"Question\",\n          \"name\":\"When should I choose flanged instead of threaded?\",\n          \"acceptedAnswer\":{\n            \"@type\":\"Answer\",\n            \"text\":\"A flanged connection may be reviewed when the system requires larger capacity, heavier piping, easier removal, formal piping-class alignment, higher documentation requirements or a project specification that requires flanged valves.\"\n          }\n        },\n        {\n          \"@type\":\"Question\",\n          \"name\":\"Does thread size determine relieving capacity?\",\n          \"acceptedAnswer\":{\n            \"@type\":\"Answer\",\n            \"text\":\"No. Thread size does not determine relieving capacity. Required capacity depends on the relief scenario, fluid properties, relieving pressure, temperature, back pressure and selected valve capacity basis.\"\n          }\n        },\n        {\n          \"@type\":\"Question\",\n          \"name\":\"What information should I send before RFQ?\",\n          \"acceptedAnswer\":{\n            \"@type\":\"Answer\",\n            \"text\":\"Send protected equipment, relief scenario, medium and phase, operating pressure, MAWP or design pressure, set pressure, required relieving capacity, relieving temperature, back pressure, thread type, thread size, male or female connection, material requirements, standards and documents.\"\n          }\n        },\n        {\n          \"@type\":\"Question\",\n          \"name\":\"Can threaded safety valves be used for steam, gas or liquid?\",\n          \"acceptedAnswer\":{\n            \"@type\":\"Answer\",\n            \"text\":\"They may be used in selected steam, gas or liquid services, depending on valve design and project requirements. The medium, phase, pressure, temperature, capacity, seat or seal material and discharge arrangement must be confirmed before selection.\"\n          }\n        }\n      ]\n    },\n    {\n      \"@type\":\"BreadcrumbList\",\n      \"@id\":\"https:\/\/zobai.com\/blog\/what-is-a-threaded-safety-valve\/#breadcrumb\",\n      \"itemListElement\":[\n        {\n          \"@type\":\"ListItem\",\n          \"position\":1,\n          \"name\":\"Home\",\n          \"item\":\"https:\/\/zobai.com\/\"\n        },\n        {\n          \"@type\":\"ListItem\",\n          \"position\":2,\n          \"name\":\"Safety Valve Knowledge Center\",\n          \"item\":\"https:\/\/zobai.com\/knowledge-center\/\"\n        },\n        {\n          \"@type\":\"ListItem\",\n          \"position\":3,\n          \"name\":\"What Is a Threaded Safety Valve?\",\n          \"item\":\"https:\/\/zobai.com\/blog\/what-is-a-threaded-safety-valve\/\"\n        }\n      ]\n    }\n  ]\n}\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>Valve Types &amp; Connection Selection What Is a Threaded Safety Valve? A threaded safety valve is a safety valve or pressure relief valve with threaded end connections instead of flanged, welded, sanitary clamp or other connection types. This page explains what threaded connection means, when it may be considered, when it may create selection risk,&#8230;<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-55415","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/zobai.com\/it\/wp-json\/wp\/v2\/posts\/55415","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zobai.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zobai.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zobai.com\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zobai.com\/it\/wp-json\/wp\/v2\/comments?post=55415"}],"version-history":[{"count":1,"href":"https:\/\/zobai.com\/it\/wp-json\/wp\/v2\/posts\/55415\/revisions"}],"predecessor-version":[{"id":55428,"href":"https:\/\/zobai.com\/it\/wp-json\/wp\/v2\/posts\/55415\/revisions\/55428"}],"wp:attachment":[{"href":"https:\/\/zobai.com\/it\/wp-json\/wp\/v2\/media?parent=55415"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zobai.com\/it\/wp-json\/wp\/v2\/categories?post=55415"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zobai.com\/it\/wp-json\/wp\/v2\/tags?post=55415"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}